standard conditions*
Capacity is rated under the
following standard conditions |
Necessary Freezing capacity
calculation for compressor selection of WOCFIM Model
buyer |
| |
|
| Water temperature 60F (18C), incoming |
1. One refrigeration ton
(T)3.86kw(1.03TR) |
| Refrigerant evaporator temperature -15F
(-26C), |
2. Required Ton (W) |
| Condensing temperature: 95F (35C) |
3. Heat exchange facor (R)
1.15 |
thickness 7/8"(22mm) 1-1/8" (28.5mm), 1-1/8"
1-1/3(33.8) Crushed ice 3/16 - 1/4 thick can be produced by modificatioin of
cutter |
4. Correction factor according to supply water
S |
| Ambient temperature 40F -> 100F (5C ->38C), Data based
90F(33C) |
5. Evaporative temp -25C base |
| 60Hz electrical supply. Capacity will be less for higher
temperatures, 50 Hz |
CALCULATION
EXAMPLE |
| Electric supply and on units using expansion
valves. |
Required production ton :5 tons, Supply water temp 15C
Assiuming |
|
So the necessary freezing capacity is asi
follows: |
|
QKIW = T X W X R X S |
|
QKIW = T(i3.86) X W(5TON) X R(1.15) X
S(I.19)=26.I4KIW AT -25C ET |
| Specifications subject to change without